XIAMEN BAYSEN MEDICAL TECH CO., LTDAbout UsUnit 401-2, No. 1 Jinzhong Road, Huli District, Xiamen, Fujian, ChinaXiamen Baysen Medical Tech Co.,Ltd. is a high-tech bio enterprise which devotes itself to the field of fast diagnostic reagent and integrates research and development,production and sales into a whole.There are many advanced research staffs and marketing managers in the company, and all of them have rich working experience in famous Chinese and international biopharmaceutical enterprises. Numbers of notable domestic and international seicetists,who joined in the research and development team,have accumlated stable production technologies and solid research and development strength as well as advanced technologies and projects expe

One step Luteinzing  LH Rapid Diagnostic Test Kit
One step Luteinzing  LH Rapid Diagnostic Test Kit
One step Luteinzing  LH Rapid Diagnostic Test Kit
One step Luteinzing  LH Rapid Diagnostic Test Kit
One step Luteinzing  LH Rapid Diagnostic Test Kit
One step Luteinzing  LH Rapid Diagnostic Test Kit
One step Luteinzing  LH Rapid Diagnostic Test Kit
One step Luteinzing  LH Rapid Diagnostic Test Kit
One step Luteinzing  LH Rapid Diagnostic Test Kit

One step Luteinzing LH Rapid Diagnostic Test Kit

Model NO.
wz189002-LH rapid test kit
Price:
USD 1.00-1.00 / pieces
Delivery
FOB
Minimum order quantity
1000 pieces
Supply Ability
1000000.0 pieces / Month
Country of Origin
xiamen
Quantity:
  • Type:Pathological Analysis Equipments
  • Name:LH Rapid Test Kit Luteinzing Predictor Test Cassette
  • Speciment:Urine, blood
  • Methodology:Colloidal gold
  • Accuracy:99.96%
  • Storage:Room tempearture
  • Fomat:Cassette
  • Usage:Pregnancy test
  • Sensitivity:25mIU/ml
  • Read time:10 min
  • Power Source:Manual
  • Warranty:1 Year
  • After-sale Service:Online Technical Support
  • Material:Acrylic
  • Shelf Life:1years
  • Quality Certification:ce
  • Instrument classification:Class II
  • Safety standard:EN 149 -2001+A1-2009
  • Place of Origin:CN;FUJ
  • Model Number:wz189002-LH
  • Brand Name:wiz

LH Rapid Test Kit Luteinzing Predictor Test Cassette

LH Test Cassette is a self-performing immunoassay designed for the qualitative determination of Luteinizing Hormone (LH) in urine for detection and predictor of ovulation.

Features

  • Quick results read in 5 minutes
  • High accuracy over 99.1%
  • Easy use at home

This product is composed of the glass fiber strips of the monoclonal antibody against luteinizing hormone (LH), anti-mouse IgG solid cellulose nitrate membrane and the bonders of the absorptive colloidal gold - monoclonal antibody against LH. It adopts the principles of double antibody sandwich method and immunochromatography to test the LH in the urine.

Intended Use:

Model: Cassette User: for the layperson

Kit list: each pouch contains one test cassette, one dropper, and one desiccant

Specimen Collection:

The sample must be collected once each day in one of the urine cups in the kit. Use a new cup each day. For best results, try to collect urine at about the same time each day when conducting the tests. The liquid intake should be reduced for two hours before collecting the urine. The urine can be stored at room temperature for up to 8 hours or in the refrigerator for up to 24 hours. Do not freeze. If the sample was refrigerated, it must be equilibrated to room temperature before testing.

Determine the Beginning Time of Test:

The bearing-aged women should first make sure of the menstrual cycle before the test, that is to take the first day of last menstrual cycle as the beginning of a period. Since the days of the menstrual cycle of each female are different, one can consult the listed time in Periodical Testing Form, and takes it as the first day of the test. One should choose a period for the test, compare the results of the test after continuous testing for 5 days or the maximum of LH appears, and find out LH surge level. If the menstrual cycle is less than 21 days or more than 38 days, one should take tests according to the enjoining of the doctor.

Test Procedure:

Before the use please prepare a timer.

  • The test is formulated for use with fresh urine specimens. Wear a glove and use urine cup to collect urine
  • Remove the test cassette from its foil pouch.
  • Draw urine sample into the dropper, and dispense it into the sample well on the cassette (2~3 drops, approximately 100uL). Be careful not to overfill the absorbent pad.
  • Read results in 5 minutes.
  • Discard the test device after a single use in the dustbin.

Interpretation of results

Negative: One pink/purple band forms in the control region; no band is found in the test region, or the color of the test band is less intense than that of the control/reference band. The result indicates the basal LH level of the tested specimen.

Positive: Two pink/purple bands form, and the color of the test band is equal to or more intense than that of the control/reference band. This result indicates an LH surge level of the tested specimen.

Invalid: If there is no pink/purple band in the control region, the test result is invalid. Retest the sample using a new device. If the problem persists, contact your local distributor.

Warnings & Precautions

For in vitro diagnostic use only

  1. When uses this product, you should not take the hCG or the LH medicine which may influence the test result, moreover, In pregnancy, menopause or use of prophylactic drugs during the test, the result will not normal.
  2. As with all diagnostic tests, a definitive diagnostic should not be based on the results of a single test, but should only be made by the physician after all clinical and laboratory findings have been evaluated.
  3. Read directions for use carefully before performing this test. Pay attention to the position of the C and T line.
  4. Do not use beyond the labeled expiration date.
  5. Do not reuse the test devices. Discard it in the dustbin after the single use.
  6. Do not use if the pouch is damaged or opened.
  7. Do not touch the membrane located within the windows.
  8. Once open the pouch, the test device should be used immediately. Prolonged exposure to ambient humidity will cause product deterioration.
  9. Treat urine samples and used devices as if they are potentially infectious. Avoid contact with skin.
  10. Examine if the urine dropper and urine cup exist before usage.
Menstrual CycleBeginning Time of Testing
21-22 daysThe 6thday
23-24 daysThe 7thday
25 daysThe 8thday
26 daysThe 9thday
27 daysThe 10thday
28 daysThe 11thday
29 daysThe 12thday
30 daysThe 13thday
31 daysThe 14thday
32 daysThe 15thday
33 daysThe 16thday
34 daysThe 17thday
35 daysThe 18thday
36 daysThe 19thday
37 daysThe 20thday
38 daysThe 21stday

Our Company

baysen medical-1.jpg

Customers&Exhibition

baysen medical-2.jpg

Product Processing

baysen medical-3.jpg

Send Message

*
* clear input
Preview on Mobile
X
whatsapp WhatsApp
wechat WeChat
message Message
go top Top
WeChat Close
qr code
baysen2
qrcode

Send Message

*
* clear input
Choose language