XIAMEN BAYSEN MEDICAL TECH CO., LTDAbout UsUnit 401-2, No. 1 Jinzhong Road, Huli District, Xiamen, Fujian, ChinaXiamen Baysen Medical Tech Co.,Ltd. is a high-tech bio enterprise which devotes itself to the field of fast diagnostic reagent and integrates research and development,production and sales into a whole.There are many advanced research staffs and marketing managers in the company, and all of them have rich working experience in famous Chinese and international biopharmaceutical enterprises. Numbers of notable domestic and international seicetists,who joined in the research and development team,have accumlated stable production technologies and solid research and development strength as well as advanced technologies and projects expe

Factory supply the microaluminuria rapid test kit urine rapid test
Factory supply the microaluminuria rapid test kit urine rapid test

Factory supply the microaluminuria rapid test kit urine rapid test

Model NO.
WZ189002- Ag
Delivery
FOB
Quantity:
  • Name:Alb Rapid Test Kit (Colloidal Gold)
  • Certificate:ISO13485
  • Usage:home use
  • Accuracy:over 99.5%
  • Material:Plastic
  • Format:Cassete
  • Package:25T/Box
  • Reading time:10-15 Minutes
  • Storage:2-30'C
  • MOQ:1000 Pcs
  • Power Source:Manual
  • Warranty:1 Year
  • After-sale Service:Online Technical Support
  • Material:Acrylic
  • Shelf Life:1years
  • Quality Certification:MSDS
  • Instrument classification:Class II
  • Safety standard:EN 149 -2001+A1-2009
  • Place of Origin:CN;FUJ
  • Model Number:WZ189002- Ag
  • Brand Name:wiz

Factory supply the microaluminuria rapid test kit urine rapid test 

 

Product Description

Alb_conew1.jpg

PACKAGE SIZE

1 kit /box, 10 kits /box, 25 kits,/box, 50 kits /box

 

Applicable instrument

Exceptvisual inspection, the kit can be matched with

Continuous immune analyzer WIZ-A202 of Xiamen Wiz Biotech Co., Ltd 

ASSAY PROCEDURE

TheWIZ-A202 test procedure see the instruction ofContinuous immune analyzer. Visual test procedureisas follows 

1. Take out the test card from the foil bag, put it on the level table and mark it;

2. Add10μlserum or plasma sample or 20ulwhole blood sample to sample well of the card with provided dispette, then add 100μl (about2-3 drop) sample diluent; start timing;

3. Wait for a minimum 10-15 minutes and read the result, the result is invalid after 15 minutes.

 

Our Company

baysen medical-1.jpg 

Customers&Exhibition

baysen medical-2.jpg 

Product Processing

baysen medical-3.jpg 

Send Message

*
* clear input
Preview on Mobile
X
whatsapp WhatsApp
wechat WeChat
message Message
go top Top
WeChat Close
qr code
baysen2
qrcode

Send Message

*
* clear input
Choose language